C9500-24Q-10E Specification
|
Product Code |
C9500-24Q-10E |
Product Description |
9500 10Y DNA Essentials, HW |
Dimensions (H x W x D) |
1.73 x 17.5 x 21.52 in |
Rack units (RU)
|
1 RU
|
Minimum software requirement |
Open Cisco IOS XE Software Release 16.5.1a |
ASIC
|
UADP 2.0
|
Switching capacity
|
Up to 1920 Gbps
|
Forwarding rate
|
Up to 1440 Mpps
|
Total number of MAC addresses
|
Up to 64,000
|
Total number of IPv4 routes (Address Resolution Protocol [ARP] plus learned routes)
|
Up to 64,000 indirect
Up to 80,000 host
|
Total number of IPv6 routes
|
Up to 32,000 indirect
Up to 40,000 host
|
Total number of IPv4 Multicast routes
|
Up to 32,000
|
Total number of IPv6 Multicast routes
|
Up to 16,000
|
QoS ACL scale
|
Up to 18000
|
Security ACL scale
|
Up to 18000
|
FNF entries
|
Up to 512,000
|
DRAM
|
16 GB
|
Flash
|
16 GB
|
VLAN IDs
|
4094
|
Total Switched Virtual Interfaces (SVIs)
|
4000
|
Jumbo frame
|
9198 bytes
|
Safety certifications
|
C9500-12Q, C9500-24Q, C9500-40X,C9500-16X
•UL 60950-1
•CAN/CSA-C22.2 No. 60950-1
•EN 60950-1
•IEC 60950-1
•AS/NZS 60950-1
•GB4943
C9500-32C, C9500-32QC, C9500-24Y4C, C9500-48Y4C
•IEC 60950-1 plus Am1, Am2 Am9, Am10, Am11, Am12 and all deviations and differences
•AS/NZS 60950.1.2011
•CAN/CSA-C22.2 No. 60950-1-07
•GB 4943-95
•EN 60950-1; 2006 plus Am1, Am 2, Am9, Am10, Am11, Am12 and all deviations and differences
•NOM-019-SCFI-1998
•UL 60950-1, Second Edition
|
EMI and EMC compliance
|
•47 CFR Part 15 Class A
•CNS13438: 2006 Class A
•EN 300 386 V1.6.1
•EN61000-3-2: 2014
•EN61000-3-3: 2013
•ICES-003 Issue 6: 2016 Class A
•KN 32: 2015 Class A
•TCVN 7189: 2009 Class A
•EN 55032:2012/ AC:2013 Class A
•EN 55032:2015 Class A
•CISPR 32 Edition 2 Class A
•V-2/2015.04 Class A
•V-3/2015.04 Class A
•CISPR24: 2010 + A1: 2015
•EN 300 386 V1.6.1
•EN55024: 2010 + A1: 2015
•KN35: 2015
•TCVN 7317: 2003
|
Input voltage
|
90 to 264 VAC
|
Operating temperature
|
32°to 104°F (0°to 40°C) |
Storage temperature
|
-4°to 149°F (-20°to 65°C) |
Relative humidity operating and nonoperating noncondensing
|
Ambient (noncondensing) operating: 5% to 90%
Ambient (noncondensing) nonoperating and storage: 5% to 95%
|
NEBS criteria levels
|
NEBS:
•Normal operating temperature range: 5C to 40C (up to 1829 meters (6000 ft)
•Short term operating temperature range: -5C to 55C
•Normal Relative Humidity range: 5% to 85%
•Short term Relative Humidity range: 5% to 93%
•Operating Altitude: up to 1829 m (6000 ft) at 55C
•ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations.
•SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue
|
Altitude
|
Operation up to 13,000 feet at 40°C |
MTBF (hours)
|
230,770
|